Categories/Technical Area:    Safety PbLi loop/Fusion
City/Country:    Italy / BOLOGNA
Institution/Company:    ENEA BRASIMONE
Facility Name:    THALLIUM
Link with which DataBase:    STC2016
Contact Person:    M.UTILI marco.utili@enea.it
Facility Short Description:    HE-FUS3 facility is designed to study the cooling circuit of HCPB-HCLL TBMs in ITER. It is able to carry out experiments up to scale 1:1. The loop is designed to operate at the following operative modes: long term isothermal cooling flow; slow thermal cycling flow; fast cold thermal shock flow; LOCA/LOFA simulation.
How Can Facilities Be Accessed by Third Parties:    person



Categories/Technical Area:    Safety PbLi/water intercation
City/Country:    Italy / BOLOGNA
Institution/Company:    ENEA BRASIMONE
Facility Name:    LIFUS V
Link with which DataBase:    STC2016
Contact Person:    A. DEL NEVO alessandro.delnevo@enea.it
Facility Short Description:    The experimental facility THALLIUM (Test HAmmer in Lead LithIUM) was designed to experimental validate the RELAP5-3D code simulations of the pressure wave propagation in the HCLL TBM due to In-box LOCA. THALLIUM, which reproduces the geometry of the PbLi loop of the HCLL TBM.
How Can Facilities Be Accessed by Third Parties:    person



Categories/Technical Area:    Erosion of Material in Lithium/purification system
City/Country:    Italy / BOLOGNA
Institution/Company:    ENEA BRASIMONE
Facility Name:    LIFUS VI
Link with which DataBase:    STC2016
Contact Person:    A. DEL NEVO alessandro.delnevo@enea.it
Facility Short Description:    Lifus 5 is an experimental facility for HLM/water interaction investigations (i.e. PbLi, LBE, Pb). It was designed to operate in a wide range of conditions: up to 200 bar and 500 °C. Lifus 5 is suitable for code validation, models development, safety analysis studies and testing engineering solutions.
How Can Facilities Be Accessed by Third Parties:   



Categories/Technical Area:    Tritium extraction technologies from PbLi/Fusion
City/Country:    Italy / BOLOGNA
Institution/Company:    ENEA BRASIMONE
Facility Name:    TRIEX
Link with which DataBase:    STC2016
Contact Person:    M.UTILI marco.utili@enea.it
Facility Short Description:    Perform experimental activities on compatibility of structural materials and Li purification technology in support of IFMIF project. The mission of the facility is to Investigate on Tritium Extraction Systems for Pb-16Li blankets (ITER and DEMO)
How Can Facilities Be Accessed by Third Parties:   



Categories/Technical Area:    Coolant chemistry /Materials
City/Country:    Italy / GENOVA
Institution/Company:    CNR/ICMATE
Facility Name:    CORAL
Link with which DataBase:   
Contact Person:    E.RICCI enrica.ricci@ge.cnr.icmate.it
Facility Short Description:    The apparatus aims to study the chemical behavior of liquid alloys and their interaction with the most promising structural materials in the working conditions of interest for the Generation IV Nuclear Fast and ADS Reactors cooled with liquid lead and lead alloys.
How Can Facilities Be Accessed by Third Parties:    person



Categories/Technical Area:    Coolant chemistry /Materials
City/Country:    Italy / GENOVA
Institution/Company:    CNR/ICMATE
Facility Name:    CORAL-TWIN
Link with which DataBase:   
Contact Person:    E.RICCI enrica.ricci@ge.cnr.icmate.it
Facility Short Description:    The apparatus, equpped with duble furnaces, both aimed to study the chemical behavior of liquid alloys and their interaction with the most promising structural materials in the working conditions of interest for the Generation IV Nuclear Fast and ADS Reactors cooled with liquid lead and lead alloys.
How Can Facilities Be Accessed by Third Parties:    person



Categories/Technical Area:    Not considered because it is not applicable to perform materials testing
City/Country:    Italy / ISPRA-VARESE
Institution/Company:    JRC-ITU
Facility Name:    PRERLa
Link with which DataBase:    STC2016
Contact Person:    Willem.JANSSENS@ec.europa.eu
Facility Short Description:   
How Can Facilities Be Accessed by Third Parties:   



Categories/Technical Area:    Coating deposition technologies/ Materials/ Surface engineering
City/Country:    Italy / MILANO
Institution/Company:    CNR/ IFP
Facility Name:    R2008
Link with which DataBase:   
Contact Person:    E. VASSALLO espedito.vassallo@cnr.ifp.it
Facility Short Description:    The apparatus aims to deposit functional coatings by means of the Physical Vapour Deposition method (enhcanced with the direct sputtering approach). The method allows the production of coatings that can be considered to prevent wear, galling, fretting, corrosion, oxidation of internal components of next generation fission and fusion reactors.
How Can Facilities Be Accessed by Third Parties:    person



Categories/Technical Area:    Coating deposition technologies/ Materials/ Surface engineering
City/Country:    Italy / PADOVA
Institution/Company:    CNR/ICMATE
Facility Name:    HiPIMS equipment
Link with which DataBase:   
Contact Person:    Enrico MIORIN enrico.miorin@cnr.it
Facility Short Description:    High Power Impulse Magnetron Sputtering (HiPIMS) is a method for physical vapor deposition of films. HIPIMS utilises extremely high power densities (order of kW?cm?2) in short pulses of tens of ms at low duty cycle. Main advantages of HIPIMS are: - great adhesion improvement; - deposition of ultra-dense coatings; - highly controlled microstructures; - increased hardness /elastic modulus; - very smooth surface morphology; uniform properties even on complex shape substrates. High performance HiPIMS coatings can be evaluated for future fission and fusion reactors components.
How Can Facilities Be Accessed by Third Parties:    person



Categories/Technical Area:   
City/Country:    Italy / PADOVA
Institution/Company:    CONSORZIO RFX
Facility Name:    NIO 1
Link with which DataBase:    STC2016
Contact Person:    Vanni Antoni vanni.antoni@igi.cnr.it
Facility Short Description:    Negative ion source
How Can Facilities Be Accessed by Third Parties:    Consorzio RFX